In any building, the ductwork links every floor and room together. In normal operation it carries conditioned air. In a fire, if left uncontrolled, the same ducts can carry flames and smoke quickly through the whole building.
A fire damper is installed where a duct passes through a fire-rated wall or floor. When a fire breaks out, its blade closes tightly, keeping the fire within one compartment and giving occupants more time to evacuate.
At our Da Nang factory, GSC – Green Supply Central Region manufactures two fire damper lines: FD EI, mechanically operated by a thermal fuse, and MFD EI, operated by a motor. Both are rated EI30 to EI120 and comply with QCVN 06:2022/BXD, Vietnam's national fire safety regulation.
The FD EI damper (code GSC.FD-EI) closes automatically when the temperature rises, with no power supply needed, so it still works if the building's power is cut during a fire.

Fitting the blade and fusible link mechanism of an FD EI damper at the GSC factory.
General ventilation systems, stair pressurization and smoke extraction systems in factories, industrial parks and civil buildings that require fire safety acceptance.
The MFD EI damper (code GSC.MFD-EI) connects directly to the fire alarm system and closes or opens its blade as soon as it receives a signal, enabling active fire zoning and smoke control.

MFD EI dampers with motor housing and pre-wired signal cable.
High-rise buildings, shopping malls, hotels, and smoke extraction and pressurization systems that must integrate with the fire alarm system.
Selection tip: the motor must be compatible with the control panel, and the signal must be wired correctly so the damper closes fully during fire safety acceptance. GSC advises on motor type and damper status right from the drawing take-off stage.
Choose FD EI for a simple solution that does not depend on power. Choose MFD EI when the damper must be controlled from the fire alarm system.
| Criteria | FD EI damper | MFD EI damper |
|---|---|---|
| Activation | 72°C / 95°C thermal fuse + spring | Motor, by fire alarm signal |
| Power supply | Not required | Power and signal required |
| Remote control | No | Yes |
| Status | Normally open, closes automatically in a fire | Normally closed or normally open |
| Fire rating | EI30 – EI120 | EI30 – EI120 |
| Cost | Lower | Higher (motor included) |
| Best for | Factories, industrial parks, general ventilation | High-rise buildings, malls, hotels, smoke extraction |
Not sure which one suits your project? Send us your drawings and the GSC technical team will do the take-off and advise.
Every GSC fire damper is fabricated, assembled and packed in our own factory, with no middlemen. This lets GSC control quality, dimensions and delivery schedules for every project.

Step 1: galvanized steel casings next to the coil production line.

Step 2: casings and blades lined with fire-rated board.

Step 3: wiring the motor of an MFD EI damper.

Step 4: inspecting and marking the size of every damper.

Step 5: dampers shrink-wrapped on pallets, ready for delivery.

Fire damper assembly area, run to 5S standards.

EI fire-rated ducts and galvanized ducts made at the same factory.
Our team's motto hangs on the factory wall: “How you do anything is how you do everything.” A small damper in the ceiling may sit untouched for years, but when it is needed, it must close correctly the very first time.
Whether your project needs FD EI, MFD EI or both, GSC builds to the exact dimensions on your drawings, supplies quality documents for fire safety acceptance and quotes on the same day.